Geant4 Cross Reference

Cross-Referencing   Geant4
Geant4/examples/extended/electromagnetic/TestEm12/berger/EGSnrc/

Version: [ ReleaseNotes ] [ 1.0 ] [ 1.1 ] [ 2.0 ] [ 3.0 ] [ 3.1 ] [ 3.2 ] [ 4.0 ] [ 4.0.p1 ] [ 4.0.p2 ] [ 4.1 ] [ 4.1.p1 ] [ 5.0 ] [ 5.0.p1 ] [ 5.1 ] [ 5.1.p1 ] [ 5.2 ] [ 5.2.p1 ] [ 5.2.p2 ] [ 6.0 ] [ 6.0.p1 ] [ 6.1 ] [ 6.2 ] [ 6.2.p1 ] [ 6.2.p2 ] [ 7.0 ] [ 7.0.p1 ] [ 7.1 ] [ 7.1.p1 ] [ 8.0 ] [ 8.0.p1 ] [ 8.1 ] [ 8.1.p1 ] [ 8.1.p2 ] [ 8.2 ] [ 8.2.p1 ] [ 8.3 ] [ 8.3.p1 ] [ 8.3.p2 ] [ 9.0 ] [ 9.0.p1 ] [ 9.0.p2 ] [ 9.1 ] [ 9.1.p1 ] [ 9.1.p2 ] [ 9.1.p3 ] [ 9.2 ] [ 9.2.p1 ] [ 9.2.p2 ] [ 9.2.p3 ] [ 9.2.p4 ] [ 9.3 ] [ 9.3.p1 ] [ 9.3.p2 ] [ 9.4 ] [ 9.4.p1 ] [ 9.4.p2 ] [ 9.4.p3 ] [ 9.4.p4 ] [ 9.5 ] [ 9.5.p1 ] [ 9.5.p2 ] [ 9.6 ] [ 9.6.p1 ] [ 9.6.p2 ] [ 9.6.p3 ] [ 9.6.p4 ] [ 10.0 ] [ 10.0.p1 ] [ 10.0.p2 ] [ 10.0.p3 ] [ 10.0.p4 ] [ 10.1 ] [ 10.1.p1 ] [ 10.1.p2 ] [ 10.1.p3 ] [ 10.2 ] [ 10.2.p1 ] [ 10.2.p2 ] [ 10.2.p3 ] [ 10.3 ] [ 10.3.p1 ] [ 10.3.p2 ] [ 10.3.p3 ] [ 10.4 ] [ 10.4.p1 ] [ 10.4.p2 ] [ 10.4.p3 ] [ 10.5 ] [ 10.5.p1 ] [ 10.6 ] [ 10.6.p1 ] [ 10.6.p2 ] [ 10.6.p3 ] [ 10.7 ] [ 10.7.p1 ] [ 10.7.p2 ] [ 10.7.p3 ] [ 10.7.p4 ] [ 11.0 ] [ 11.0.p1 ] [ 11.0.p2 ] [ 11.0.p3, ] [ 11.0.p4 ] [ 11.1 ] [ 11.1.1 ] [ 11.1.2 ] [ 11.1.3 ] [ 11.2 ] [ 11.2.1 ] [ 11.2.2 ] [ 11.3.0 ]

Name Size       Last modified (GMT) Description
Back Parent directory       2024-12-05 15:16:16
File 100keV-DPK.ascii 322 bytes       2024-12-05 15:16:16
File 10keV-DPK.ascii 321 bytes       2024-12-05 15:16:16
File 15keV-DPK.ascii 321 bytes       2024-12-05 15:16:16
File 1MeV-DPK.ascii 323 bytes       2024-12-05 15:16:16
File README 640 bytes       2024-12-05 15:16:16

  1 ------------------
  2 EGSnrc Simulations
  3 ------------------
  4 
  5 These results were computed with the EGSnrc user code EDKnrc,
  6 developed by E. Mainegra et al.
  7   Yann Perrot (perrot@clermont.in2p3.fr)  December 2010
  8 
  9 Simulation parameters:
 10 ----------------------
 11 
 12 Electron Stepping Algorithm : PRESTA-II
 13 Boundary Crossing Algoritm : EXACT with skin parameter=3
 14 Maximum Energy Loss per Step : ESTEPE = 1%
 15 Electron tracking cut : 10keV for E>=1MeV
 16       1keV for E<1MeV     
 17 
 18 References:
 19 ----------
 20 
 21 Mainegra et al 2005
 22 Med. Phys. 32, 685-99
 23 
 24 Rogers et al 2003
 25 NRC User Codes for EGSnrc
 26 Technical Report PIRS-702(RevB)