Version: [ ReleaseNotes ] [ 1.0 ] [ 1.1 ] [ 2.0 ] [ 3.0 ] [ 3.1 ] [ 3.2 ] [ 4.0 ] [ 4.0.p1 ] [ 4.0.p2 ] [ 4.1 ] [ 4.1.p1 ] [ 5.0 ] [ 5.0.p1 ] [ 5.1 ] [ 5.1.p1 ] [ 5.2 ] [ 5.2.p1 ] [ 5.2.p2 ] [ 6.0 ] [ 6.0.p1 ] [ 6.1 ] [ 6.2 ] [ 6.2.p1 ] [ 6.2.p2 ] [ 7.0 ] [ 7.0.p1 ] [ 7.1 ] [ 7.1.p1 ] [ 8.0 ] [ 8.0.p1 ] [ 8.1 ] [ 8.1.p1 ] [ 8.1.p2 ] [ 8.2 ] [ 8.2.p1 ] [ 8.3 ] [ 8.3.p1 ] [ 8.3.p2 ] [ 9.0 ] [ 9.0.p1 ] [ 9.0.p2 ] [ 9.1 ] [ 9.1.p1 ] [ 9.1.p2 ] [ 9.1.p3 ] [ 9.2 ] [ 9.2.p1 ] [ 9.2.p2 ] [ 9.2.p3 ] [ 9.2.p4 ] [ 9.3 ] [ 9.3.p1 ] [ 9.3.p2 ] [ 9.4 ] [ 9.4.p1 ] [ 9.4.p2 ] [ 9.4.p3 ] [ 9.4.p4 ] [ 9.5 ] [ 9.5.p1 ] [ 9.5.p2 ] [ 9.6 ] [ 9.6.p1 ] [ 9.6.p2 ] [ 9.6.p3 ] [ 9.6.p4 ] [ 10.0 ] [ 10.0.p1 ] [ 10.0.p2 ] [ 10.0.p3 ] [ 10.0.p4 ] [ 10.1 ] [ 10.1.p1 ] [ 10.1.p2 ] [ 10.1.p3 ] [ 10.2 ] [ 10.2.p1 ] [ 10.2.p2 ] [ 10.2.p3 ] [ 10.3 ] [ 10.3.p1 ] [ 10.3.p2 ] [ 10.3.p3 ] [ 10.4 ] [ 10.4.p1 ] [ 10.4.p2 ] [ 10.4.p3 ] [ 10.5 ] [ 10.5.p1 ] [ 10.6 ] [ 10.6.p1 ] [ 10.6.p2 ] [ 10.6.p3 ] [ 10.7 ] [ 10.7.p1 ] [ 10.7.p2 ] [ 10.7.p3 ] [ 10.7.p4 ] [ 11.0 ] [ 11.0.p1 ] [ 11.0.p2 ] [ 11.0.p3, ] [ 11.0.p4 ] [ 11.1 ] [ 11.1.1 ] [ 11.1.2 ] [ 11.1.3 ] [ 11.2 ] [ 11.2.1 ] [ 11.2.2 ] [ 11.3.0 ]

  1 # Example eFLASH_radiotherapy History
  2 
  3 See `CONTRIBUTING.rst` for details of **required** info/format for each entry,
  4 which **must** added in reverse chronological order (newest at the top). It must **not**
  5 be used as a substitute for writing good git commit messages!
  6 
  7 ## 2024-11-09 G. Milluzzo (eFLASH_radiotherapy-V11-02-02)
  8 - Added a new geometry in DetectorConstruction:added an array of multiple small size silicon carbide detectors within the water phantom for dose distribution computation
  9 - Added the sensitive detector class for the silicon carbide array
 10 - Updated the macro files
 11 
 12 ## 2024-08-12 I. Hrivnacova (eFLASH_radiotherapy-V11-02-01)
 13 - Removed unused includes of G4Accumulable[Manager].hh from FlashRunAction
 14 
 15 ## 2024-01-10 G. Milluzzo (eFLASH_radiotherapy-V11-02-00)
 16 - Added the FlashPhysicsListMessenger class to change the physics lists by macro commands (opt3,opt4,penelope and livermore)
 17 
 18 ## 2023-11-15 I. Hrivnacova (eFLASH_radiotherapy-V11-01-02)
 19 - Updated vis.mac:
 20   - Changed "/vis/open XYZ [600x600-0+0]" to "/vis/open" to allow run-time choices
 21     and simplified comments.
 22 
 23 ## 2023-11-10 A. Ribon (eFLASH_radiotherapy-V11-01-01)
 24 - In all macro files, introduced the UI command
 25   '/process/had/rdm/thresholdForVeryLongDecayTime 1.0e+60 year'
 26   to allow all radioactive decays (including the very long ones).
 27   This is necessary since G4 11.2, being 1 year the default time
 28   threshold above which the decays are ignored.
 29 
 30 ## 2023-06-19 G. Milluzzo (eFLASH_radiotherapy-V11-01-00)