Geant4 Cross Reference

Cross-Referencing   Geant4
Geant4/examples/extended/electromagnetic/TestEm15/README

Version: [ ReleaseNotes ] [ 1.0 ] [ 1.1 ] [ 2.0 ] [ 3.0 ] [ 3.1 ] [ 3.2 ] [ 4.0 ] [ 4.0.p1 ] [ 4.0.p2 ] [ 4.1 ] [ 4.1.p1 ] [ 5.0 ] [ 5.0.p1 ] [ 5.1 ] [ 5.1.p1 ] [ 5.2 ] [ 5.2.p1 ] [ 5.2.p2 ] [ 6.0 ] [ 6.0.p1 ] [ 6.1 ] [ 6.2 ] [ 6.2.p1 ] [ 6.2.p2 ] [ 7.0 ] [ 7.0.p1 ] [ 7.1 ] [ 7.1.p1 ] [ 8.0 ] [ 8.0.p1 ] [ 8.1 ] [ 8.1.p1 ] [ 8.1.p2 ] [ 8.2 ] [ 8.2.p1 ] [ 8.3 ] [ 8.3.p1 ] [ 8.3.p2 ] [ 9.0 ] [ 9.0.p1 ] [ 9.0.p2 ] [ 9.1 ] [ 9.1.p1 ] [ 9.1.p2 ] [ 9.1.p3 ] [ 9.2 ] [ 9.2.p1 ] [ 9.2.p2 ] [ 9.2.p3 ] [ 9.2.p4 ] [ 9.3 ] [ 9.3.p1 ] [ 9.3.p2 ] [ 9.4 ] [ 9.4.p1 ] [ 9.4.p2 ] [ 9.4.p3 ] [ 9.4.p4 ] [ 9.5 ] [ 9.5.p1 ] [ 9.5.p2 ] [ 9.6 ] [ 9.6.p1 ] [ 9.6.p2 ] [ 9.6.p3 ] [ 9.6.p4 ] [ 10.0 ] [ 10.0.p1 ] [ 10.0.p2 ] [ 10.0.p3 ] [ 10.0.p4 ] [ 10.1 ] [ 10.1.p1 ] [ 10.1.p2 ] [ 10.1.p3 ] [ 10.2 ] [ 10.2.p1 ] [ 10.2.p2 ] [ 10.2.p3 ] [ 10.3 ] [ 10.3.p1 ] [ 10.3.p2 ] [ 10.3.p3 ] [ 10.4 ] [ 10.4.p1 ] [ 10.4.p2 ] [ 10.4.p3 ] [ 10.5 ] [ 10.5.p1 ] [ 10.6 ] [ 10.6.p1 ] [ 10.6.p2 ] [ 10.6.p3 ] [ 10.7 ] [ 10.7.p1 ] [ 10.7.p2 ] [ 10.7.p3 ] [ 10.7.p4 ] [ 11.0 ] [ 11.0.p1 ] [ 11.0.p2 ] [ 11.0.p3, ] [ 11.0.p4 ] [ 11.1 ] [ 11.1.1 ] [ 11.1.2 ] [ 11.1.3 ] [ 11.2 ] [ 11.2.1 ] [ 11.2.2 ] [ 11.3.0 ]

Diff markup

Differences between /examples/extended/electromagnetic/TestEm15/README (Version 11.3.0) and /examples/extended/electromagnetic/TestEm15/README (Version 6.1)


  1 ----------------------------------------------    
  2                                                   
  3      =========================================    
  4      Geant4 - an Object-Oriented Toolkit for S    
  5      =========================================    
  6                                                   
  7                             TestEm15              
  8                             --------              
  9                                                   
 10         How to compute and plot the final stat    
 11    - Multiple Scattering                          
 12    - Gamma Conversion                             
 13   considered as an isolated processes, see PHY    
 14                                                   
 15   For Multiple Scattering, the method is expos    
 16                                                   
 17   For Gamma Conversion, when G4BetheHeitler5DM    
 18   see README.gamma for Histograms and UI comma    
 19                                                   
 20  1- GEOMETRY DEFINITION                           
 21                                                   
 22         It is a single box representing a 'sem    
 23         Two parameters define the geometry:       
 24         - the material of the box,                
 25         - the (full) size of the box.             
 26                                                   
 27         The default geometry (100 m of water)     
 28         DetectorConstruction, but the above pa    
 29         interactively via the commands defined    
 30                                                   
 31  2- PHYSICS LIST                                  
 32                                                   
 33         The physics list contains the standard    
 34         In order not to introduce 'artificial'    
 35         there is no limitation from the maximu    
 36                                                   
 37  3- AN EVENT: THE PRIMARY GENERATOR               
 38                                                   
 39         The primary kinematic consists of a si    
 40         of the box. The type of the particle a    
 41         PrimaryGeneratorAction (1 MeV electron    
 42         build-in commands of ParticleGun class    
 43         this example).                            
 44                                                   
 45  4- PHYSICS                                       
 46                                                   
 47         All discrete processes are inactivated    
 48         so that Multiple Scattering or Gamma C    
 49         determine the first step of the primar    
 50         The step size and the final state are     
 51         Then the event is immediately killed.     
 52                                                   
 53   Multiple Scattering:                            
 54                                                   
 55   The result is compared with the 'input' data    
 56         sections stored in the PhysicsTables a    
 57         The stepMax command provides an additi    
 58         the multiple scattering.                  
 59                                                   
 60                                                   
 61  5- HISTOGRAMS                                    
 62                                                   
 63         The test contains 16 built-in 1D histo    
 64         G4AnalysisManager and its Messenger. T    
 65         activated with the command:               
 66         /analysis/h1/set id nbBins  valMin val    
 67         where unit is the desired unit for the    
 68         (see the macros xxxx.mac).                
 69                                                   
 70         1       Multiple Scattering. True step    
 71         2       Multiple Scattering. Geom step    
 72         3       Multiple Scattering. Ratio geo    
 73         4       Multiple Scattering. Lateral d    
 74         5       Multiple Scattering. Lateral d    
 75         6       Multiple Scattering. Angular d    
 76         7       Multiple Scattering. Phi-posit    
 77         8       Multiple Scattering. Phi-direc    
 78         9       Multiple Scattering. Correlati    
 79                                                   
 80         10      Gamma Conversion. Open Angle *    
 81         11      Gamma Conversion. Log10(P reco    
 82         12      Gamma Conversion. Phi P recoil    
 83         13      Gamma Conversion. Phi P plus a    
 84         14      Gamma Conversion. 2 * cos(phip    
 85         15      Gamma Conversion. E plus / E g    
 86         16      Gamma Conversion. Phi of Gamma    
 87                                                   
 88                                                   
 89    The histograms are managed by the HistoMana    
 90    The histos can be individually activated wi    
 91    /analysis/h1/set id nbBins  valMin valMax u    
 92    where unit is the desired unit for the hist    
 93                                                   
 94    One can control the name of the histograms     
 95    /analysis/setFileName  name  (default teste    
 96                                                   
 97    It is possible to choose the format of the     
 98    hdf5, xml, csv, by changing the default fil    
 99                                                   
100    It is also possible to print selected histo    
101    /analysis/h1/setAscii id                       
102    All selected histos will be written on a fi    
103                                                   
104  6- VISUALIZATION                                 
105                                                   
106         The Visualization Manager is set in th    
107         The initialization of the drawing is d    
108         /vis/... in the macro vis.mac. To get     
109         > /control/execute vis.mac                
110                                                   
111         The detector has a default view which     
112         box.                                      
113                                                   
114         The tracks are drawn at the end of eve    
115                                                   
116  7- HOW TO START ?                                
117                                                   
118         execute TestEm15 in 'batch' mode from     
119                 % TestEm15   compt.mac            
120                                                   
121         execute TestEm15 in 'interactive mode'    
122                 % TestEm15                        
123                 Idle> control/execute vis.mac     
124                 ....                              
125                 Idle> type your commands          
126                 ....                              
127                 Idle> exit                        
128                                                   
129 8 - MACROS                                        
130        The examples of macros for Multiple Sca    
131        electron.mac muon.mac  proton.mac          
132                                                   
133        The example of Gamma Conversion macro:     
134        gamma.mac - gamma to e+ e-                 
135        gamma2mumu.mac gamma to mu+ mu-