Geant4 Cross Reference

Cross-Referencing   Geant4
Geant4/examples/advanced/microbeam/README

Version: [ ReleaseNotes ] [ 1.0 ] [ 1.1 ] [ 2.0 ] [ 3.0 ] [ 3.1 ] [ 3.2 ] [ 4.0 ] [ 4.0.p1 ] [ 4.0.p2 ] [ 4.1 ] [ 4.1.p1 ] [ 5.0 ] [ 5.0.p1 ] [ 5.1 ] [ 5.1.p1 ] [ 5.2 ] [ 5.2.p1 ] [ 5.2.p2 ] [ 6.0 ] [ 6.0.p1 ] [ 6.1 ] [ 6.2 ] [ 6.2.p1 ] [ 6.2.p2 ] [ 7.0 ] [ 7.0.p1 ] [ 7.1 ] [ 7.1.p1 ] [ 8.0 ] [ 8.0.p1 ] [ 8.1 ] [ 8.1.p1 ] [ 8.1.p2 ] [ 8.2 ] [ 8.2.p1 ] [ 8.3 ] [ 8.3.p1 ] [ 8.3.p2 ] [ 9.0 ] [ 9.0.p1 ] [ 9.0.p2 ] [ 9.1 ] [ 9.1.p1 ] [ 9.1.p2 ] [ 9.1.p3 ] [ 9.2 ] [ 9.2.p1 ] [ 9.2.p2 ] [ 9.2.p3 ] [ 9.2.p4 ] [ 9.3 ] [ 9.3.p1 ] [ 9.3.p2 ] [ 9.4 ] [ 9.4.p1 ] [ 9.4.p2 ] [ 9.4.p3 ] [ 9.4.p4 ] [ 9.5 ] [ 9.5.p1 ] [ 9.5.p2 ] [ 9.6 ] [ 9.6.p1 ] [ 9.6.p2 ] [ 9.6.p3 ] [ 9.6.p4 ] [ 10.0 ] [ 10.0.p1 ] [ 10.0.p2 ] [ 10.0.p3 ] [ 10.0.p4 ] [ 10.1 ] [ 10.1.p1 ] [ 10.1.p2 ] [ 10.1.p3 ] [ 10.2 ] [ 10.2.p1 ] [ 10.2.p2 ] [ 10.2.p3 ] [ 10.3 ] [ 10.3.p1 ] [ 10.3.p2 ] [ 10.3.p3 ] [ 10.4 ] [ 10.4.p1 ] [ 10.4.p2 ] [ 10.4.p3 ] [ 10.5 ] [ 10.5.p1 ] [ 10.6 ] [ 10.6.p1 ] [ 10.6.p2 ] [ 10.6.p3 ] [ 10.7 ] [ 10.7.p1 ] [ 10.7.p2 ] [ 10.7.p3 ] [ 10.7.p4 ] [ 11.0 ] [ 11.0.p1 ] [ 11.0.p2 ] [ 11.0.p3, ] [ 11.0.p4 ] [ 11.1 ] [ 11.1.1 ] [ 11.1.2 ] [ 11.1.3 ] [ 11.2 ] [ 11.2.1 ] [ 11.2.2 ] [ 11.3.0 ]

Diff markup

Differences between /examples/advanced/microbeam/README (Version 11.3.0) and /examples/advanced/microbeam/README (Version 5.2.p2)


  1 ----------------------------------------------    
  2 ----------------------------------------------    
  3                                                   
  4      =========================================    
  5       Geant4 - Microbeam example                  
  6      =========================================    
  7                                                   
  8                                 README file       
  9                           --------------------    
 10                                                   
 11                            CORRESPONDING AUTHO    
 12                                                   
 13 S. Incerti (a, *) et al.                          
 14 a. Centre d'Etudes Nucleaires de Bordeaux-Grad    
 15 (CENBG), IN2P3 / CNRS / Bordeaux 1 University,    
 16 * e-mail:incerti@cenbg.in2p3.fr                   
 17                                                   
 18 ---->0. INTRODUCTION.                             
 19                                                   
 20 The microbeam example simulates the cellular i    
 21 installed on the AIFIRA electrostatic accelera    
 22 CENBG, Bordeaux-Gradignan, France. For more in    
 23 please visit :                                    
 24 http://www.cenbg.in2p3.fr/                        
 25                                                   
 26 ---->1. GEOMETRY SET-UP.                          
 27                                                   
 28 The elements simulated are:                       
 29                                                   
 30 1. A switching dipole magnet with fringing fie    
 31 beam generated by the electrostatic accelerato    
 32 oriented at 10 degrees from the main beam dire    
 33                                                   
 34 2. A circular collimator object, defining the     
 35 microbeam line entrance;                          
 36                                                   
 37 3. A quadrupole based magnetic symmetric focus    
 38 transverse demagnifications of 10. Fringe fiel    
 39 model.                                            
 40                                                   
 41 4. A dedicated cellular irradiation chamber se    
 42                                                   
 43 5. A set of horizontal and vertical electrosta    
 44 be turned on or off to deflect the beam on tar    
 45                                                   
 46 6. A realistic human keratinocyte voxellized c    
 47 microscopy and taking into account realistic n    
 48 compositions.                                     
 49                                                   
 50                                                   
 51 ---->2. EXPERIMENTAL SET-UP.                      
 52                                                   
 53 The beam is defined at the microbeam line entr    
 54 5 micrometer in diameter. The beam is then foc    
 55 quadruplet of quadrupoles in the so-called Dym    
 56 The beam is sent to the irradiation chamber wh    
 57 isobutane gas detector for counting purpose be    
 58 culture foil of the target cell which is immer    
 59 enclosed within a dish.                           
 60                                                   
 61 A cell is placed on the polypropylene foil and    
 62 microbeam. The cell is represented through a 3    
 63 obtained from confocal microscopy. In the prov    
 64 are : 359 nm (X) x 359 nm (Y) x 163 nm (Z)        
 65                                                   
 66 The primary particle beam parameters are gener    
 67 measurements performed on the AIFIRA facility.    
 68 cellular irradiation are 3 MeV alpha particles    
 69                                                   
 70 More details on the experimental setup and its    
 71 be found in the following papers:                 
 72                                                   
 73 - IN SILICO NANODOSIMETRY: NEW INSIGHTS INTO N    
 74 RADIATION                                         
 75 By Z. Kuncic, H. L. Byrne, A. L. McNamara, S.     
 76 Publsihed in Comp. Math. Meth. Med. (2012) 147    
 77                                                   
 78 - MONTE CARLO MICRODOSIMETRY FOR TARGETED IRRA    
 79 A MICROBEAM FACILITY                              
 80 By S. Incerti, H. Seznec, M. Simon, Ph. Barber    
 81 Published in Rad. Prot. Dos. 133, 1 (2009) 2-1    
 82                                                   
 83 - MONTE CARLO SIMULATION OF THE CENBG MICROBEA    
 84 GEANT4 TOOLKIT                                    
 85 By S. Incerti, Q. Zhang, F. Andersson, Ph. Mor    
 86 M.J. Merchant, D.T. Nguyen, C. Habchi, T. Pout    
 87 Published in Nucl. Instrum. and Meth. B 260 (2    
 88                                                   
 89 - A COMPARISON OF CELLULAR IRRADIATION TECHNIQ    
 90 THE GEANT4 MONTE CARLO SIMULATION TOOLKIT         
 91 By S. Incerti, N. Gault, C. Habchi, J.L.. Lefa    
 92 T. Pouthier, H. Seznec. Dec 2006. 3pp.            
 93 Published in Rad. Prot. Dos. 122, 1-4, (2006)     
 94                                                   
 95 - GEANT4 SIMULATION OF THE NEW CENBG MICRO AND    
 96 By S. Incerti, C. Habchi, Ph. Moretto, J. Oliv    
 97 Published in Nucl.Instrum.Meth.B249:738-742, 2    
 98                                                   
 99 - A COMPARISON OF RAY-TRACING SOFTWARE FOR THE    
100 SYSTEMS                                           
101 By S. Incerti et al.,                             
102 Published in Nucl.Instrum.Meth.B231:76-85, 200    
103                                                   
104 - DEVELOPMENT OF A FOCUSED CHARGED PARTICLE MI    
105 INDIVIDUAL CELLS.                                 
106 By Ph. Barberet, A. Balana, S. Incerti, C. Mic    
107 Th. Pouthier. Dec 2004. 6pp.                      
108 Published in Rev.Sci.Instrum.76:015101, 2005      
109                                                   
110 - SIMULATION OF CELLULAR IRRADIATION WITH THE     
111 GEANT4.                                           
112 By S. Incerti, Ph. Barberet, R. Villeneuve, P.    
113 C. Michelet-Habchi, Ph. Moretto, D.T. Nguyen,     
114 Published in IEEE Trans.Nucl.Sci.51:1395-1401,    
115                                                   
116 - SIMULATION OF ION PROPAGATION IN THE MICROBE    
117 GEANT4.                                           
118 By S. Incerti, Ph. Barberet, B. Courtois, C. M    
119 Ph. Moretto. Sep 2003.                            
120 Published in Nucl.Instrum.Meth.B210:92-97, 200    
121                                                   
122                                                   
123 ---->3 VISUALIZATION                              
124                                                   
125 The user can visualize the targeted cell thank    
126                                                   
127 ---->4. HOW TO RUN THE EXAMPLE                    
128                                                   
129 The code should be compiled with cmake.           
130                                                   
131 Run the example from your build directory with    
132 ./microbeam microbeam.mac                         
133                                                   
134 or in interactive mode:                           
135 ./microbeam                                       
136                                                   
137 The example works in MT mode.                     
138                                                   
139 ---->5. PHYSICS                                   
140                                                   
141 Livermore physics list is used by default.        
142                                                   
143 ---->6. SIMULATION OUTPUT AND RESULT ANALYZIS     
144                                                   
145 The output results consist in a microbeam.root    
146 containing several ntuples:                       
147                                                   
148 * total deposited dose in the cell nucleus and    
149 cytoplasm by each incident alpha particle;        
150                                                   
151 * average on the whole run of the dose deposit    
152 Voxel per incident alpha particle;                
153                                                   
154 * final stopping (x,y,z) position of the incid    
155 alpha particle within the irradiated medium (c    
156                                                   
157 * stopping power dE/dx of the incident            
158 alpha particle just before penetrating into th    
159                                                   
160 * beam transverse position distribution (X and    
161 just before penetrating into the targeted cell    
162                                                   
163 These results can be easily analyzed using for    
164 file plot.C; to do so :                           
165 * be sure to have ROOT installed on your machi    
166 * be sure to be in the directory where the out    
167 * do: root plot.C                                 
168 * or under your ROOT session, type in : .X plo    
169                                                   
170 ----------------------------------------------    
171                                                   
172 Should you have any enquiry, please do not hes    
173 incerti@cenbg.in2p3.fr