Geant4 Cross Reference

Cross-Referencing   Geant4
Geant4/examples/advanced/iort_therapy/README

Version: [ ReleaseNotes ] [ 1.0 ] [ 1.1 ] [ 2.0 ] [ 3.0 ] [ 3.1 ] [ 3.2 ] [ 4.0 ] [ 4.0.p1 ] [ 4.0.p2 ] [ 4.1 ] [ 4.1.p1 ] [ 5.0 ] [ 5.0.p1 ] [ 5.1 ] [ 5.1.p1 ] [ 5.2 ] [ 5.2.p1 ] [ 5.2.p2 ] [ 6.0 ] [ 6.0.p1 ] [ 6.1 ] [ 6.2 ] [ 6.2.p1 ] [ 6.2.p2 ] [ 7.0 ] [ 7.0.p1 ] [ 7.1 ] [ 7.1.p1 ] [ 8.0 ] [ 8.0.p1 ] [ 8.1 ] [ 8.1.p1 ] [ 8.1.p2 ] [ 8.2 ] [ 8.2.p1 ] [ 8.3 ] [ 8.3.p1 ] [ 8.3.p2 ] [ 9.0 ] [ 9.0.p1 ] [ 9.0.p2 ] [ 9.1 ] [ 9.1.p1 ] [ 9.1.p2 ] [ 9.1.p3 ] [ 9.2 ] [ 9.2.p1 ] [ 9.2.p2 ] [ 9.2.p3 ] [ 9.2.p4 ] [ 9.3 ] [ 9.3.p1 ] [ 9.3.p2 ] [ 9.4 ] [ 9.4.p1 ] [ 9.4.p2 ] [ 9.4.p3 ] [ 9.4.p4 ] [ 9.5 ] [ 9.5.p1 ] [ 9.5.p2 ] [ 9.6 ] [ 9.6.p1 ] [ 9.6.p2 ] [ 9.6.p3 ] [ 9.6.p4 ] [ 10.0 ] [ 10.0.p1 ] [ 10.0.p2 ] [ 10.0.p3 ] [ 10.0.p4 ] [ 10.1 ] [ 10.1.p1 ] [ 10.1.p2 ] [ 10.1.p3 ] [ 10.2 ] [ 10.2.p1 ] [ 10.2.p2 ] [ 10.2.p3 ] [ 10.3 ] [ 10.3.p1 ] [ 10.3.p2 ] [ 10.3.p3 ] [ 10.4 ] [ 10.4.p1 ] [ 10.4.p2 ] [ 10.4.p3 ] [ 10.5 ] [ 10.5.p1 ] [ 10.6 ] [ 10.6.p1 ] [ 10.6.p2 ] [ 10.6.p3 ] [ 10.7 ] [ 10.7.p1 ] [ 10.7.p2 ] [ 10.7.p3 ] [ 10.7.p4 ] [ 11.0 ] [ 11.0.p1 ] [ 11.0.p2 ] [ 11.0.p3, ] [ 11.0.p4 ] [ 11.1 ] [ 11.1.1 ] [ 11.1.2 ] [ 11.1.3 ] [ 11.2 ] [ 11.2.1 ] [ 11.2.2 ] [ 11.3.0 ]

Diff markup

Differences between /examples/advanced/iort_therapy/README (Version 11.3.0) and /examples/advanced/iort_therapy/README (Version 10.4)


  1                                                     1 
  2        =======================================      2        =========================================================
  3                      Text version of the iort_      3                      Text version of the iort_therapy README file
  4              =================================      4              =========================================================
  5                                                     5 
                                                   >>   6 Last revision: C.Casarino, October 2014;
                                                   >>   7 Released with the Geant4 10.0 version (December 2013)
                                                   >>   8  
                                                   >>   9 
                                                   >>  10 
                                                   >>  11 
                                                   >>  12              =========================================================
                                                   >>  13                                        iort_therapy
                                                   >>  14              =========================================================
                                                   >>  15 
  6  Main Authors:                                     16  Main Authors:
  7  G.Russo(a,b), C.Casarino*(c), G.C. Candiano(c     17  G.Russo(a,b), C.Casarino*(c), G.C. Candiano(c), G.A.P. Cirrone(d), F.Romano(d)
  8                                                    18  
  9  Contributor Authors:                              19  Contributor Authors:
 10  S.Guatelli(e)                                     20  S.Guatelli(e)
 11                                                    21 
 12  Past Authors:                                     22  Past Authors:
 13  G.Arnetta(c), S.E.Mazzaglia(d)                    23  G.Arnetta(c), S.E.Mazzaglia(d)
 14                                                    24 
 15  (a) Fondazione Istituto San Raffaele G.Giglio <<  25  (a) Fondazione Istituto San Raffaele G.Giglio, Cefalù, Italy
 16                                                    26 
 17  (b) IBFM-CNR , Segrate (Milano), Italy            27  (b) IBFM-CNR , Segrate (Milano), Italy
 18                                                    28 
 19  (c) LATO (Laboratorio di Tecnologie Oncologic <<  29  (c) LATO (Laboratorio di Tecnologie Oncologiche), Cefalù, Italy
 20                                                    30  
 21  (d) Laboratori Nazionali del Sud of the INFN,     31  (d) Laboratori Nazionali del Sud of the INFN, Catania, Italy
 22                                                    32 
 23  (e) University of Wollongong, Australia       <<  33  (e) University of Wallongong, Australia
 24                                                    34 
 25                                                    35 
 26   *Corresponding author, email to carlo.casari     36   *Corresponding author, email to carlo.casarino@polooncologicocefalu.it
 27 ----------------------------------------------     37 -------------------------------------------------------------------------------------------------
 28                                                    38 
 29 iort_therapy:                                      39 iort_therapy:
 30                                                    40 
 31 WHAT IT IS, WHAT IT DOES AND WHAT IT WILL PROV     41 WHAT IT IS, WHAT IT DOES AND WHAT IT WILL PROVIDE          
 32                                                    42 
 33 iort_therapy is a Geant4-based application spe     43 iort_therapy is a Geant4-based application specifically developed to address typical needs related to the Intra-Operative Radio-Therapy (IORT) technique. 
 34                                                    44  
 35 iort_therapy is capable to simulate a well spe <<  45 iort_therapy is capable to simulate a well specified intra-operative electron radio-therapy facility: the collimator beam line system of a typical medical mobile linac and the relative target (water-phantom). iort_therapy application is currently used by the G.Russo team in clinical and research activities carried out in Fondazione Istituto San Raffaele G.Giglio Hospital (Cefalù, Italy) where a NOVAC7 linac is installed.
 36                                                    46 
 37 iort_therapy, is flexible and show many capabi     47 iort_therapy, is flexible and show many capabilities. Its geometrical set-up, for example, is completely interchangeable permitting a simple switch between different geometrical collimator system configurations; the possibility to simulate a composite metallic shielding disc inside the water-phantom was also implemented.
 38                                                    48 
 39                                                    49 
 40 Folder structure of iort_therapy                   50 Folder structure of iort_therapy
 41                                                    51 
 42 iort_therapy distribution contain these sub-fo     52 iort_therapy distribution contain these sub-folders:
 43                                                    53 
 44 \src: where source .cc files are stored            54 \src: where source .cc files are stored
 45 \include: where header .hh files are stored        55 \include: where header .hh files are stored
                                                   >>  56 \macro: where a set of ready-to-use macro files are provided
                                                   >>  57 
 46                                                    58 
 47 Currently this folders structure is in develop     59 Currently this folders structure is in development and in the meanwhile new features and capabilities will be added. 
 48                                                    60 
 49                                                    61 
 50 DOWNLOAD AND INSTALLATION                          62 DOWNLOAD AND INSTALLATION
 51                                                    63 
 52 iort_therapy source code is released inside th     64 iort_therapy source code is released inside the official distribution of the Geant4 toolkit in the $G4INSTALL/examples/AdvancedExamples folder.
 53                                                    65 
 54 To run iort_therapy you must first install the     66 To run iort_therapy you must first install the Geant4 package. Once Geant4 is installed the example must be first compiled (with the command gmake inside the
 55 ../iort_therapy folder). When compilation is c     67 ../iort_therapy folder). When compilation is completed the program can be executed.
 56                                                    68 
 57 A CMakeLists.txt file is provided together wit     69 A CMakeLists.txt file is provided together with a standard GNUmakefile for compilation. 
 58                                                    70 
 59 A complete guide for the Geant4 installation i     71 A complete guide for the Geant4 installation in different operating systems can be found inside the official installation Geant4 pages.
 60                                                    72 
                                                   >>  73 If you have troubles with the Geant4 installation please send an e-mail to us.
                                                   >>  74 
                                                   >>  75 
 61                                                    76 
 62 GEOMETRICAL SET-UP                                 77 GEOMETRICAL SET-UP
 63                                                    78 
 64 The idea of iort_therapy is to provide a tool      79 The idea of iort_therapy is to provide a tool useful for Users interested in the field of electron intra-operative radio-therapy. These can include the simple calculation of dose distribution curves in water or other materials, the possibility to study and plan dose distribution in the tumor treatment region with different clinical set-up, and to optimize radio-protection of normal patient tissues simulating a composite metallic shielding disc.
 65                                                    80 
 66 The main component of the simulation is the co     81 The main component of the simulation is the collimator beam line system, the phantom, the detector and the composite metallic shielding disc.
 67                                                    82 
 68                                                    83 
 69 COLLIMATOR BEAM LINE SYSTEM                        84 COLLIMATOR BEAM LINE SYSTEM
 70                                                    85 
 71 At moment iort_therapy include the simulation      86 At moment iort_therapy include the simulation of a collimator beam line system, based on a typical medical mobile linac structure us the NOVAC7. This  collimator beam line is elaborated in the files CollimatorXXBeamLine.cc , where XX may be 40, 50, 60, 70 ,80 or 100 (mm) depending on the diameter collimator set-up chosen. 
 72 In fact, there is also a facility in iort_ther     87 In fact, there is also a facility in iort_therapy that allows the user to make a choice, via macro, between alternative collimator beam line set-up. This can be done by using command:
 73                                                    88 
 74 /geometrySetup/selectGeometry <name>               89 /geometrySetup/selectGeometry <name>
 75                                                    90 
 76 where <name> is coll40, coll50, coll60, coll70     91 where <name> is coll40, coll50, coll60, coll70, coll80 or coll100 depending on the diameter collimator set-up chosen (40mm, 50mm, 60mm, 70mm, 80mm or 100mm). The standard "default" geometry is coll60.
 77                                                    92 
 78 The Collimator beam line system class file         93 The Collimator beam line system class file
 79                                                    94 
 80 The following is the description of the elemen     95 The following is the description of the elements of the collimator beam line system from the accelerator head to the final collimator. This line is completely simulated inside this class.
 81                                                    96 
 82 The main elements are the accelerator head and     97 The main elements are the accelerator head and the applicator.
 83 The accelerator head performs as a primary col     98 The accelerator head performs as a primary collimator system. It consists of titanium exit window and a cylindrical PMMA structure where two monitor chambers are installed.
 84 The applicator consists of a cylindrical PMMA      99 The applicator consists of a cylindrical PMMA tube (the final collimator). In the order we have implemented the following functions:
 85                                                   100 
 86   IortBeamLineVacuumSource();                     101   IortBeamLineVacuumSource();
 87   IortBeamLineTitaniumWindows();                  102   IortBeamLineTitaniumWindows();
 88   IortBeamLineMonitorChambers();                  103   IortBeamLineMonitorChambers();
 89   IortBeamLineBlocks() ;                          104   IortBeamLineBlocks() ;
 90   IortBeamLineJunctions();                        105   IortBeamLineJunctions(); 
 91   IortBeamLineFinalCollimator();                  106   IortBeamLineFinalCollimator();
 92                                                   107 
                                                   >> 108 
                                                   >> 109 
 93 The user has now the possibility to vary, via     110 The user has now the possibility to vary, via messenger, the inner and outer radius of the final collimator.
 94                                                   111 
 95                                                   112 
 96 THE PHANTOM                                       113 THE PHANTOM 
 97                                                   114 
 98 At the end of the beam line a phantom (a box o    115 At the end of the beam line a phantom (a box of 20cmx20cmx20cm default dimensions) is reproduced.
 99 Inside it, a user-defined region (the detector    116 Inside it, a user-defined region (the detector) is divided (via the ROGeomtry classes of Geant4) in cubic and identical voxels. The voxels size can be varied as well as the voxelized region.
100 At the end of a simulation run the dose deposi    117 At the end of a simulation run the dose deposited by primaries and secondaries in each voxel is collected. This information is available as an .out file.  
101                                                   118 
102 THE DETECTOR                                      119 THE DETECTOR
103                                                   120 
104 A scoring mesh is set to score the dose in the << 121 The default sizes of the sensible voxelized region (detector) are 7cmx15cmx15cm and actually the default voxel configuration is   0.5mm x 0.5mm x 0.5mm, which means a matrix of 140x300x300 cubic voxels each with a lateral dimension of 0.5 mm. Of course this default can be modified.
105                                                   122 
106 As concern the cut and stepMax values, the def    123 As concern the cut and stepMax values, the default configuration implies a cut value of 0.01 mm in the whole  world (use the command /physic/setCuts <length>  in order to set the cut for all, and the command /physic/setDetectorCuts <length> to set the cut for the detector only)  and a stepMax of 0.01 mm just in the phantom (use the command /Step/waterPhantomStepMax 0.01 mm).
107 In any case it is strongly recommended to use     124 In any case it is strongly recommended to use a stepMax value not bigger than 5% of the dose slice thickness.
108                                                   125 
109                                                   126 
110 SHIELDING DISC                                    127 SHIELDING DISC
111                                                   128 
112 Inside the detector is positioned a double lay    129 Inside the detector is positioned a double layered shielding disc. For both layers it is possible via macro to change the outer and inner radius, the thickness, the position along the beam axis and the material.
113 NOTE 1: to delete the disc out the entire geom << 130 ADVERTISEMENT: to delete the disc out the entire geometry the relative macro command must be used!!
114 NOTE 2: to re-insert the disc in the entire ge << 131 ADVERTISEMENT: to re-insert the disc in the entire geometry the relative macro command must be used!!
115                                                   132   
                                                   >> 133  
116                                                   134 
117 PHYSICS PROCESSES AND PHYSICS MODELS IMPLEMENT    135 PHYSICS PROCESSES AND PHYSICS MODELS IMPLEMENTATION
118                                                   136 
119 EM Standard option 4 is activated. The user ca << 137  Physics models in iort_therapy, following the Geant4 organization, can be defined using two different approaches:
                                                   >> 138 
                                                   >> 139 
                                                   >> 140 Activating one of the 'Reference Physics Lists' that are already prepared by the Geant4 Collaboration and are contained in the $G4INSTALL/source/physics_lists/lists folderlist.
                                                   >> 141 The 'Reference Physics Lists' can be activated setting a specific environment variable to the name of the physics. For example if the QGSP_BIC Reference Physics Lists  must be activated the User must set export PHYSLIST=QGSP_BIC (or setenv PHYSLIST QGSP_BIC). A 'Reference Physics Lists' contains all the physics process necessary to a particle  transport.
                                                   >> 142 If  the  User set the PHYSLIST variable,  iort_therapy  will  start  with  the             defaultMacroWithReferencePhysicsList.mac macro. See this macro file for more details.
                                                   >> 143 Activating the 'Builders' already prepared by the Geant4 Collaboration and contained in the $G4INSTALL/source/physics_lists/builder folder.
                                                   >> 144 Each builder is specific  of  a  given  model.  There  are  builders  for  the  electromagnetic processes, for the hadronic one, etc.
                                                   >> 145 If the PHYSLIST variable is not defined iort_therapy starts with the defaultMacro.mac where the single builders are activated for the various processes of interest.
                                                   >> 146 Each builder is activated with the /Physics/addPhysics <nome builder> command.
                                                   >> 147 
                                                   >> 148 
                                                   >> 149        ******       SUGGESTED PHYSICS       *********
                                                   >> 150 
                                                   >> 151     AT MOMENT, IF ACCURATE RESULTS ARE NEDED, WE STRONGLY RECOMMEND: 
                                                   >> 152     1. The use of the emstandard_opt3, or
                                                   >> 153     2. the QGSP_BIC_EMY Reference Physics Lists (define the PHYSLIST evironment variable):
                                                   >> 154        export PHYSLIST=QGSP_BIC_EMY
                                                   >> 155 A particular care is addressed to the simulation of the physic processes.
120                                                   156 
121                                                   157 
122 INTERACTIVE COMMANDS                              158 INTERACTIVE COMMANDS
123                                                   159 
                                                   >> 160 
                                                   >> 161 
124 How to change Phantom, Detector and Shielding     162 How to change Phantom, Detector and Shielding Disc geometries
125                                                   163 
126 In order to let the end user to change phantom    164 In order to let the end user to change phantom and detector geometries and voxelization, some interactive commands have been provided. All parameters are mandatory, except those inside square brackets.
127                                                   165 
128                                                   166 
129 Phantom geometry                                  167 Phantom geometry
130                                                   168 
131 (1) The phantom size. As usually, zero or nega    169 (1) The phantom size. As usually, zero or negatives values mean: <<don't change it>>.
132 (2) The phantom position respect to the world.    170 (2) The phantom position respect to the world. In this case specified values refer to the three components of the position of the phantom's center respect to the world's.
133                                                   171 
134 Command synopsis:                                 172 Command synopsis:
135                                                   173 
136 /changePhantom/size <dimX> <dimY> <dimZ> <[uni    174 /changePhantom/size <dimX> <dimY> <dimZ> <[unit]> # 20 20 20 cm
137 /changePhantom/position <posX> <posY> <posZ> <    175 /changePhantom/position <posX> <posY> <posZ> <[unit]> # 4.5 0 0 cm
138                                                   176 
139                                                   177 
140 Detector geometry                                 178 Detector geometry 
141                                                   179 
142 The user can change:                              180 The user can change:
143                                                   181 
144 (1) The detector (box) size.                      182 (1) The detector (box) size.
145                                                   183  
146 (2) The displacement between the phantom and t << 184 (2) The voxels sizes. Changing this parameters, and/or the detector sizes, user should choose values in order to be divisors of the detector correspondent sizes.
                                                   >> 185 For both above commands, zero or negative values mean << don't change it >>
                                                   >> 186 
                                                   >> 187 (3) The displacement between the phantom and the detector.  Displacement parameters refer to the lower left corner of the detector respect to that of the phantom, by the point of view of the beam. In this case zero or positive values are allowed, while the negatives ones mean: << don't change it>>.
                                                   >> 188 
147                                                   189 
148 Command synopsis:                                 190 Command synopsis:
                                                   >> 191 
                                                   >> 192 
149 /changeDetector/size <dimX> <dimY> <dimZ> <[un    193 /changeDetector/size <dimX> <dimY> <dimZ> <[unit]>
                                                   >> 194 /changeDetector/voxelSize <dimX> <dimY> <dimZ> <[unit]> 
150 /changeDetector/displacement <dispX> <dispY> <    195 /changeDetector/displacement <dispX> <dispY> <dispZ> <[unit]> 
151                                                   196 
152 The user has to change the scoring mesh accord << 197 Default size values are 7x15x15 cm for the detector, 0.5x0.5x0.5 mm for any voxel. The default detector position is chosen so that the 15x15 detector face is aligned and centered respect the detector beam exposed face.
                                                   >> 198 
153                                                   199 
154                                                   200 
155 Shielding Disc geometry                           201 Shielding Disc geometry
156                                                   202 
157 Command synopsis:                                 203 Command synopsis:
158                                                   204 
159 /ProtectionDisc1/OuterRadiusDisc1 <dim>           205 /ProtectionDisc1/OuterRadiusDisc1 <dim>       # default -> 40*mm ; 
160 /ProtectionDisc1/InnerRadiusDisc1 <dim>           206 /ProtectionDisc1/InnerRadiusDisc1 <dim>       # default -> 0*mm
161 /ProtectionDisc1/HeightDisc1      <dim>           207 /ProtectionDisc1/HeightDisc1      <dim>       # default -> 2*mm
162 /ProtectionDisc1/XPositionDisc1  <dimX>           208 /ProtectionDisc1/XPositionDisc1  <dimX>       # default -> -11*mm   
163 /ProtectionDisc1/material    <G4_Material>        209 /ProtectionDisc1/material    <G4_Material>    # default -> G4_WATER ;
164                                                   210 
165 /ProtectionDisc2/OuterRadiusDisc2 <dim>           211 /ProtectionDisc2/OuterRadiusDisc2 <dim>       # default -> 40*mm ;
166 /ProtectionDisc2/InnerRadiusDisc2 <dim>           212 /ProtectionDisc2/InnerRadiusDisc2 <dim>       # default -> 0*mm
167 /ProtectionDisc2/HeightDisc2      <dim>           213 /ProtectionDisc2/HeightDisc2      <dim>       # default -> 1*mm
168 /ProtectionDisc2/XPositionDisc2  <dimX>           214 /ProtectionDisc2/XPositionDisc2  <dimX>       # default -> -8*mm
169 /ProtectionDisc2/material    <G4_Material>        215 /ProtectionDisc2/material    <G4_Material>    # default -> G4_WATER ;
170                                                   216 
171                                                   217 
172 All   these    commands    must be   followed     218 All   these    commands    must be   followed   by the  command  /changePhantom/update
173 in order to check and eventually apply changes    219 in order to check and eventually apply changes to the real geometry.
174 Moreover  they  must   be    issued  between      220 Moreover  they  must   be    issued  between   runs  (so   where you   want but   after  the /run/initialize initialization command, or the G4State_Idle Geant4 state machine).
175 Obviously all the previous sizes must be set i    221 Obviously all the previous sizes must be set in order to maintain the detector fully inside the phantom, otherwise system complains.
176                                                   222 
177                                                   223 
178 To Delete Disc geometry                           224 To Delete Disc geometry
179                                                   225 
180 Command synopsis:                                 226 Command synopsis:
181                                                   227 
182 /DeleteProtectionDisc/delete                      228 /DeleteProtectionDisc/delete
183                                                   229 
184 To Re-insert Disc geometry                        230 To Re-insert Disc geometry
185                                                   231 
186 Command synopsis:                                 232 Command synopsis:
187                                                   233 
188 /InsertProtectionDisc/insert                      234 /InsertProtectionDisc/insert
189                                                   235 
190 **** To set initial beam features              << 236  
                                                   >> 237 Stopping powers calculation
                                                   >> 238 
                                                   >> 239 It is possible for the end-user to calculate, via macro command, stopping powers only for those materials inserted into G4NistMaterialBuilder class (about 300).
                                                   >> 240 To get stopping powers user must provide this command line on the idle interactive terminal (or into a macro file) :
                                                   >> 241 
                                                   >> 242 /parameter/getstopping <G4_material> <Emin> <Emax> <nPoints> <[particle]> <[output_filename]>
                                                   >> 243 
                                                   >> 244 All parameters are mandatory except those inside square brackets [].
                                                   >> 245 Default values for parameters inside square brackets are respectively proton and standard output (usually the user console terminal).
                                                   >> 246 
                                                   >> 247 Parameters are respectively:
                                                   >> 248 
                                                   >> 249 The material (NIST) name (something like G4_..., the complete list of elements and materials is available into the G4NistMaterialBuilder class and can be printed  to the terminal screen via the macro command: /parameter/nist )
                                                   >> 250 Kinetic energy range in MeV and the number of data points to be retrieved (in a logarithmically uniform space)
                                                   >> 251 The particle name (proton, e+, e-, He3, neutron,... a full list can be gotten via the macro command: /particle/list).
                                                   >> 252          Only for ions, user must firstly give them to the particle gun, for example issuing the  macro commands:
                                                   >> 253 /gun/particle ion
                                                   >> 254 /gun/ion <Z> <A> <[charge]>
                                                   >> 255 The output filename: if users leave this blank then the standard output is used.
                                                   >> 256 
                                                   >> 257 Below is an example in order to calculate the stopping power for alphas into Hydrogen between 1 keV to 150 MeV for 15 points:
                                                   >> 258 
                                                   >> 259 /parameter/getstopping G4_H 0.001 150 15 alpha 
                                                   >> 260 
                                                   >> 261 # and for C12 ion:
                                                   >> 262 
                                                   >> 263 /gun/particle ion
                                                   >> 264 /gun/ion 6 12 6
                                                   >> 265 /parameter/getstopping G4_H 0.001 150 15 C12[0.0]
                                                   >> 266 
                                                   >> 267 # Value inside square brackets is the excitation energy of the ion (ground state in this case).
                                                   >> 268 
                                                   >> 269 
                                                   >> 270 To set initial beam features
191                                                   271 
192 By default, the beam propagates along the posi    272 By default, the beam propagates along the positive X direction with Gaussian momentum and Y-Z distributions. 
193 It is possible to select: particle type, mean     273 It is possible to select: particle type, mean energy and relative standard deviation, X,Y and Z coordinates, Y and Z standard deviations and, finally, the beam spread along X direction (Theta). 
194                                                   274 
195 Command synopsis:                                 275 Command synopsis:
196                                                   276 
197 /gun/particle                                     277 /gun/particle 
198 /beam/energy/meanEnergy                           278 /beam/energy/meanEnergy 
199 /beam/energy/sigmaEnergy                          279 /beam/energy/sigmaEnergy  
200 /beam/position/Xposition                          280 /beam/position/Xposition
201 /beam/position/Yposition                          281 /beam/position/Yposition
202 /beam/position/Yposition/sigmaY                   282 /beam/position/Yposition/sigmaY
203 /beam/position/Zposition                          283 /beam/position/Zposition
204 /beam/position/Zposition/sigmaZ                   284 /beam/position/Zposition/sigmaZ 
205 /beam/momentum/Theta                              285 /beam/momentum/Theta
206                                                   286  
                                                   >> 287 
                                                   >> 288 
207 HOW RUN iort_therapy                              289 HOW RUN iort_therapy
208                                                   290 
209 Run the example in interactive mode               291 Run the example in interactive mode                                      
210                                                   292 
211 > $G4WORDIR/bin/Linux-g++/iort_therapy            293 > $G4WORDIR/bin/Linux-g++/iort_therapy
212                                                   294 
213 In this case the main file (iort_therapy.cc) p    295 In this case the main file (iort_therapy.cc) performs different operations depending on which environment variable is activated;
214 For example, if the environment variable G4UI_    296 For example, if the environment variable G4UI_USE_TCSH is activated, iort_therapy will start with the TCSH User Interface that has many useful functionalities. On the other hand, if this first variables is not defined, the program will continue searching for the G4UI_USE_QT variable and, finally, will open the standard G4UITerminal.
215                                                   297 
216 Run the example using macro files                 298 Run the example using macro files          
217                                                   299 
218 iort_therapy can be launched using a macro fil    300 iort_therapy can be launched using a macro file:
219                                                   301 
220 > $G4WORDIR/bin/Linux-g++/iort_therapy macroFi    302 > $G4WORDIR/bin/Linux-g++/iort_therapy macroFile.mac
221                                                   303 
222 The defaultMacro.mac file is contained in the     304 The defaultMacro.mac file is contained in the main directory of iort_therapy and is automatically read in case the user launch the executable without a parameter.
223                                                   305 
224                                                   306 
225 SIMULATION OUTPUT                                 307 SIMULATION OUTPUT
226                                                   308 
227 Store results in an ASCII file                    309 Store results in an ASCII file
228                                                   310 
229 A .out ASCII file is generated at the end of e << 311 A .out ASCII file is generated at the end of each run, Dose.out is its default name that can be changed in the IORTMatrix.cc file.
230 The file contains four columns; the first thre << 312 The file contains four columns; the first three columns represent the voxel indexes (that univocally identify the voxel volume), while the last column represents the dose deposited in that given voxel.
                                                   >> 313 
                                                   >> 314 
                                                   >> 315 FUTURE CHALLENGES
                                                   >> 316 
                                                   >> 317 This is a list of future components that will be added in iort_therapy.
                                                   >> 318 
                                                   >> 319 In the next future iort_therapy will be improved making it possible to simulate roto-translations of the collimator beam    line respect the target thus reproducing the mobility characteristics of the linac.
                                                   >> 320 
                                                   >> 321 
                                                   >> 322 Dicom Interface
                                                   >> 323 
                                                   >> 324 A first work in progress version iort_therapy-DICOM is underdeveloped. This application imports in iort_therapy the main parts and facilities of the Dicom extended-medical example, so it permits to replace the water phantom with a voxellized phantom version of the dicom images.
                                                   >> 325 
                                                   >> 326 Human-Phantom Interface
                                                   >> 327 
                                                   >> 328 Also a second work in progress version iort_therapy-Human-Phantom is underdeveloped. It is based on the Human-Phantom advanced example. Thus there will be the possibility to replace the water phantom with the human phantom. 
                                                   >> 329 
                                                   >> 330 All these configuration will be set by macro commands.
                                                   >> 331 
231                                                   332 
                                                   >> 333 Please contact carlo.casarino@polooncologicocefalu.it for more details or suggestions and feedbacks on this document.
232                                                   334 
233                                                   335