Version: [ ReleaseNotes ] [ 1.0 ] [ 1.1 ] [ 2.0 ] [ 3.0 ] [ 3.1 ] [ 3.2 ] [ 4.0 ] [ 4.0.p1 ] [ 4.0.p2 ] [ 4.1 ] [ 4.1.p1 ] [ 5.0 ] [ 5.0.p1 ] [ 5.1 ] [ 5.1.p1 ] [ 5.2 ] [ 5.2.p1 ] [ 5.2.p2 ] [ 6.0 ] [ 6.0.p1 ] [ 6.1 ] [ 6.2 ] [ 6.2.p1 ] [ 6.2.p2 ] [ 7.0 ] [ 7.0.p1 ] [ 7.1 ] [ 7.1.p1 ] [ 8.0 ] [ 8.0.p1 ] [ 8.1 ] [ 8.1.p1 ] [ 8.1.p2 ] [ 8.2 ] [ 8.2.p1 ] [ 8.3 ] [ 8.3.p1 ] [ 8.3.p2 ] [ 9.0 ] [ 9.0.p1 ] [ 9.0.p2 ] [ 9.1 ] [ 9.1.p1 ] [ 9.1.p2 ] [ 9.1.p3 ] [ 9.2 ] [ 9.2.p1 ] [ 9.2.p2 ] [ 9.2.p3 ] [ 9.2.p4 ] [ 9.3 ] [ 9.3.p1 ] [ 9.3.p2 ] [ 9.4 ] [ 9.4.p1 ] [ 9.4.p2 ] [ 9.4.p3 ] [ 9.4.p4 ] [ 9.5 ] [ 9.5.p1 ] [ 9.5.p2 ] [ 9.6 ] [ 9.6.p1 ] [ 9.6.p2 ] [ 9.6.p3 ] [ 9.6.p4 ] [ 10.0 ] [ 10.0.p1 ] [ 10.0.p2 ] [ 10.0.p3 ] [ 10.0.p4 ] [ 10.1 ] [ 10.1.p1 ] [ 10.1.p2 ] [ 10.1.p3 ] [ 10.2 ] [ 10.2.p1 ] [ 10.2.p2 ] [ 10.2.p3 ] [ 10.3 ] [ 10.3.p1 ] [ 10.3.p2 ] [ 10.3.p3 ] [ 10.4 ] [ 10.4.p1 ] [ 10.4.p2 ] [ 10.4.p3 ] [ 10.5 ] [ 10.5.p1 ] [ 10.6 ] [ 10.6.p1 ] [ 10.6.p2 ] [ 10.6.p3 ] [ 10.7 ] [ 10.7.p1 ] [ 10.7.p2 ] [ 10.7.p3 ] [ 10.7.p4 ] [ 11.0 ] [ 11.0.p1 ] [ 11.0.p2 ] [ 11.0.p3, ] [ 11.0.p4 ] [ 11.1 ] [ 11.1.1 ] [ 11.1.2 ] [ 11.1.3 ] [ 11.2 ] [ 11.2.1 ] [ 11.2.2 ] [ 11.3.0 ]

Diff markup

Differences between /examples/advanced/composite_calorimeter/README (Version 11.3.0) and /examples/advanced/composite_calorimeter/README (Version 11.1.2)


  1 ----------------------------------------------      1 -------------------------------------------------------------------
  2 ----------------------------------------------      2 -------------------------------------------------------------------
  3                                                     3 
  4      =========================================      4      =========================================================
  5                       Geant4 - Composite calor      5                       Geant4 - Composite calorimeter example
  6      =========================================      6      =========================================================
  7                                                     7 
  8                              README                 8                              README
  9                       ---------------------         9                       ---------------------
 10                                                    10 
 11  CompositeCalorimeter is an example of a test-     11  CompositeCalorimeter is an example of a test-beam simulation used 
 12  by the CMS Collaboration to validate Geant4 a     12  by the CMS Collaboration to validate Geant4 against real data taken 
 13  (in 1996) in a CMS Hadron calorimeter test-be     13  (in 1996) in a CMS Hadron calorimeter test-beam.
 14  The name "Composite" for this example emphasi     14  The name "Composite" for this example emphasizes that, although the 
 15  test-beam had the goal of studying the hadron     15  test-beam had the goal of studying the hadronic calorimeter response, 
 16  part of the data was taken with the presence      16  part of the data was taken with the presence of the electromagnetic 
 17  crystal calorimeter in front of the hadronic      17  crystal calorimeter in front of the hadronic calorimeter, to better 
 18  reproduce the situation as in the real CMS ex     18  reproduce the situation as in the real CMS experiment. 
 19  The geometry of the simulation has been setup     19  The geometry of the simulation has been setup in such a way to allow
 20  very easily, at run time (therefore without n     20  very easily, at run time (therefore without need of changing any code; 
 21  see below for the details) the inclusion or e     21  see below for the details) the inclusion or exclusion of the 
 22  electromagnetic calorimeter part.                 22  electromagnetic calorimeter part. 
 23  Although some important aspects, for a detail     23  Although some important aspects, for a detailed comparison between 
 24  test-beam data and simulation, like beam prof     24  test-beam data and simulation, like beam profile, noise, and digitization, 
 25  have been omitted here (to avoid too many tec     25  have been omitted here (to avoid too many technical details),
 26  nevertheless, this example is able to reprodu     26  nevertheless, this example is able to reproduce the main features of
 27  most of the relevant observables as measured      27  most of the relevant observables as measured in the real test-beam. 
 28  The output of this example consists of a set      28  The output of this example consists of a set of histograms 
 29  and one ntuple which are stored on a ROOT fil     29  and one ntuple which are stored on a ROOT file (default). 
 30  In our opinion, the most original "lesson" wh     30  In our opinion, the most original "lesson" which is offered by this
 31  advanced example for the Geant4 user is to sh     31  advanced example for the Geant4 user is to show how the Geometry and
 32  the Sensitive/Hit part of the simulation is t     32  the Sensitive/Hit part of the simulation is treated in a big experiment.
 33  Although the details of how this is done vary     33  Although the details of how this is done vary from experiment to
 34  experiment (it is worth, for instance, to com     34  experiment (it is worth, for instance, to compare with the Atlas-based
 35  advanced example lAr_calorimeter), the main d     35  advanced example lAr_calorimeter), the main driving needs and goals 
 36  are quite general: to have consistency, but a     36  are quite general: to have consistency, but avoiding duplications
 37  and couplings as much as possibile, between S     37  and couplings as much as possibile, between Simulation, Reconstruction,
 38  and Visualization. Notice that the solution o     38  and Visualization. Notice that the solution offered in this example
 39  by CMS could appear "overdone" for the sake o     39  by CMS could appear "overdone" for the sake of simulating only a 
 40  relatively simple test-beam setup; but it sho     40  relatively simple test-beam setup; but it should be kept in mind
 41  that the same approach is used also for the f     41  that the same approach is used also for the full CMS detector 
 42  simulation, as well as for any subdetector.       42  simulation, as well as for any subdetector.  
 43                                                    43 
 44                                                    44   
 45 1. Setting up the environment variables            45 1. Setting up the environment variables
 46 ---------------------------------------            46 ---------------------------------------
 47                                                    47 
 48  The user should first setup, as "usual", the      48  The user should first setup, as "usual", the Geant4 environmental
 49  variables (e.g. the script produced by cmake)     49  variables (e.g. the script produced by cmake) 
 50  Then the specific setup for this example shou     50  Then the specific setup for this example should be run:
 51                                                    51  
 52      >  source envExample.csh      in the case     52      >  source envExample.csh      in the case of C-shell
 53  or                                                53  or
 54      >  . envExample.sh            in the case     54      >  . envExample.sh            in the case of bash-shell
 55                                                    55  
 56  The analysis part is based on the native g4an     56  The analysis part is based on the native g4analysis tools. As default 
 57  the output is a ROOT file. This can be change     57  the output is a ROOT file. This can be changed to XML by changing the G4AnalysisManager default file type in CCalRunAction::BeginOfRunAction().
 58                                                    58 
 59                                                    59 
 60 2. Sample run                                      60 2. Sample run
 61 -------------                                      61 -------------
 62                                                    62 
 63  Once the environmental variables are setup, y     63  Once the environmental variables are setup, you can get the executable
 64     CompositeCalorimeter                           64     CompositeCalorimeter
 65  by configuring with cmake and then running th     65  by configuring with cmake and then running the compiler.
 66  Then, you can execute it using the Geant4 mac     66  Then, you can execute it using the Geant4 macro command input file test.g4mac
 67  as follows:                                       67  as follows:    
 68                                                    68  
 69     >  ./CompositeCalorimeter test.g4mac           69     >  ./CompositeCalorimeter test.g4mac
 70                                                    70  
 71  which simulate a few events, each being a 100     71  which simulate a few events, each being a 100 GeV pi- incident on the 
 72  electromagnetic crystal calorimeter followed      72  electromagnetic crystal calorimeter followed by the hadronic calorimeter,
 73  without magnetic field.                           73  without magnetic field.
 74  The output is the ROOT file "ccal.root" .         74  The output is the ROOT file "ccal.root" .
 75  See part "8. Analysis / Histogramming" below      75  See part "8. Analysis / Histogramming" below for more details on the
 76  content of that file.                             76  content of that file.
 77  If you run instead:                               77  If you run instead: 
 78                                                    78 
 79     >  ./CompositeCalorimeter                      79     >  ./CompositeCalorimeter
 80                                                    80 
 81  after having setup the Geant4 visualization v     81  after having setup the Geant4 visualization variables and the PATH,
 82  you can visualize the geometry of the apparat     82  you can visualize the geometry of the apparatus, and also see some
 83  events. Similarly, you can get a very simple      83  events. Similarly, you can get a very simple graphical user interface
 84  that allows to select the particle type, its      84  that allows to select the particle type, its energy, and the number
 85  of events (between a limited number of possib     85  of events (between a limited number of possibilities).
 86  For more details, see part "9. Visualization      86  For more details, see part "9. Visualization / GUI".
 87                                                    87  
 88                                                    88 
 89 3. Detector description                            89 3. Detector description
 90 -----------------------                            90 -----------------------
 91                                                    91  
 92  Let's start with a brief description of the t     92  Let's start with a brief description of the test-beam setup.
 93                                                    93 
 94  There are two possible configurations:            94  There are two possible configurations: 
 95    i)  HCAL only, that is only the hadronic ca     95    i)  HCAL only, that is only the hadronic calorimeter is present;
 96   ii)  ECAL+HCAL, that is the electromagnetic      96   ii)  ECAL+HCAL, that is the electromagnetic calorimeter (ECAL)
 97                   is placed in front of the ha     97                   is placed in front of the hadronic calorimeter.
 98  ECAL is made of 23 cm long PbWO4 crystals (co     98  ECAL is made of 23 cm long PbWO4 crystals (corresponding to about
 99  25.8 radiation lengths, and 1.1 interaction l     99  25.8 radiation lengths, and 1.1 interaction lengths); for the 
100  test beam a  7 x 7 = 49  matrix of crystals i    100  test beam a  7 x 7 = 49  matrix of crystals is used.
101  HCAL is a sampling calorimeter, with plastic     101  HCAL is a sampling calorimeter, with plastic scintillator as sensitive
102  part and copper as absorber. 28 scintillator     102  part and copper as absorber. 28 scintillator plates were used with
103  absorber of varying thickness in between, and    103  absorber of varying thickness in between, and also varying thickness
104  and type of scintillator. More precisely:        104  and type of scintillator. More precisely:
105    --- layer 1: 2 cm of Copper                    105    --- layer 1: 2 cm of Copper
106    --- layer 2 to 7: 4 cm of Copper               106    --- layer 2 to 7: 4 cm of Copper
107    --- layer 8 to 21: 6 cm of Copper              107    --- layer 8 to 21: 6 cm of Copper
108    --- layer 22 to 27: 8 cm of Copper             108    --- layer 22 to 27: 8 cm of Copper
109  For the scintillators: 2 mm passive Plastic;     109  For the scintillators: 2 mm passive Plastic; 4 mm active Plastic;
110  1 mm passive Plastic.                            110  1 mm passive Plastic. 
111  The total length of HCAL consists of 152 cm o    111  The total length of HCAL consists of 152 cm of Copper plus 189 mm of Plastic.
112  The dimension orthogonal to the beam directio    112  The dimension orthogonal to the beam direction is  64 cm x 64 cm.
113  The ECAL and HCAL considered here are prototy    113  The ECAL and HCAL considered here are prototypes for the Central and
114  Endcap calorimeters of the CMS detector (whic    114  Endcap calorimeters of the CMS detector (which covers the rapidity
115  region |eta| < 3.0 ; CMS has also a Forward c    115  region |eta| < 3.0 ; CMS has also a Forward calorimeter, which covers
116  the region 3.0 < |eta| < 5.0, but this part w    116  the region 3.0 < |eta| < 5.0, but this part was not considered in 
117  this test-beam setup). Notice, however, that     117  this test-beam setup). Notice, however, that there are more layers 
118  (28 instead of 19 in the Barrel or 18 in the     118  (28 instead of 19 in the Barrel or 18 in the Endcap) of HCAL in the 
119  test-beam setup than in the real CMS detector    119  test-beam setup than in the real CMS detector, in order to study 
120  energy containment. Therefore, the ECAL+HCAL     120  energy containment. Therefore, the ECAL+HCAL in the test-beam amounts 
121  to more than 11 radiation lengths as for the     121  to more than 11 radiation lengths as for the real CMS detector (the
122  19 layers of the Barrel have each 6 cm of abs    122  19 layers of the Barrel have each 6 cm of absorber, whereas the 
123  18 layers of the Endcap have each 6.6 cm of a    123  18 layers of the Endcap have each 6.6 cm of absorber, so that the
124  number of interaction lengths are rougly the     124  number of interaction lengths are rougly the same). 
125  Five values of the magnetic field (parallel t    125  Five values of the magnetic field (parallel to the face of the scintillators)
126  have been considered in the test-beam: 0.0 ,     126  have been considered in the test-beam: 0.0 , 0.375 , 0.75 , 1.50 , 3.0 Tesla.
127                                                   127 
128  In order to set the magnetic field, you have     128  In order to set the magnetic field, you have to edit the file
129        dataglobal/fmap.tb96                       129        dataglobal/fmap.tb96
130  and change the first number (which appears in    130  and change the first number (which appears in the third line of
131  that file, on the first column; the unit bein    131  that file, on the first column; the unit being Tesla): 
132    #. Field map                                   132    #. Field map
133    *DO FLDM                                       133    *DO FLDM
134      0.0   9               652.0                  134      0.0   9               652.0
135  for example, if you want a magnetic field of     135  for example, if you want a magnetic field of 3.0 Tesla the last
136  line must be set as follows (the magnetic fie    136  line must be set as follows (the magnetic field unity is kilo Gauss).
137      30.0   9               652.0                 137      30.0   9               652.0
138                                                   138 
139  In order to deactivate either the ECAL or the    139  In order to deactivate either the ECAL or the HCAL, it is enough
140  to comment out the corresponding line in the     140  to comment out the corresponding line in the file g4testbeamhcal96.conf, 
141  using "#" as the comment character. For insta    141  using "#" as the comment character. For instance, to have only the HCAL
142  without ECAL:                                    142  without ECAL:
143  "HcalTB96"                      "tbhcal96"       143  "HcalTB96"                      "tbhcal96"              1
144  #"CrystalMatrixModule"           "tbhcal96xta    144  #"CrystalMatrixModule"           "tbhcal96xtal"          1  
145                                                   145 
146                                                   146 
147  In this test-beam setup, at the back of ECAL,    147  In this test-beam setup, at the back of ECAL, there is also some 
148  material for support and readout, which has b    148  material for support and readout, which has been considered in the 
149  simulation. For the HCAL, only the fibres are    149  simulation. For the HCAL, only the fibres are close to the test-beam, 
150  and because they have the same composition as    150  and because they have the same composition as the scintillators
151  they are adequately represented in the simula    151  they are adequately represented in the simulation; the remaining
152  of the readout, including the photomultiplier    152  of the readout, including the photomultipliers, are in readout boxes
153  far away from the HCAL, and hence are not pre    153  far away from the HCAL, and hence are not present in the simulation.
154                                                   154 
155  Let's summarizes now the geometry description    155  Let's summarizes now the geometry description of the simulation.
156  As said in the introduction, this part is the    156  As said in the introduction, this part is the most original and
157  important of this example, but it is quite co    157  important of this example, but it is quite complex and can be fully
158  appreciated only in the context of the CMS so    158  appreciated only in the context of the CMS software framework, in 
159  particular in the relation between Simulation    159  particular in the relation between Simulation, Reconstruction, and
160  Visualization. Therefore we limit ourself to     160  Visualization. Therefore we limit ourself to only few considerations,
161  pointing to the internal CMS documentation fo    161  pointing to the internal CMS documentation for more details.
162                                                   162  
163  --- In order to share the same geometrical an    163  --- In order to share the same geometrical and physical information
164      about CMS between Simulation, Reconstruct    164      about CMS between Simulation, Reconstruction, and Visualization,
165      avoiding inconsistencies, duplications, a    165      avoiding inconsistencies, duplications, and unnecessary dependecies,
166      all these information is store, once for     166      all these information is store, once for all, in common databases
167      (typically in XML format), instead of put    167      (typically in XML format), instead of putting them inside C++ classes, 
168      as usually done in simpler detector descr    168      as usually done in simpler detector descriptions (in most of the
169      the Geant4 examples, novice or advanced,     169      the Geant4 examples, novice or advanced, the geometry information
170      is kept inside the concrete class which i    170      is kept inside the concrete class which inherits from 
171      G4VUserDetectorConstruction). For simplic    171      G4VUserDetectorConstruction). For simplicity, in this example,
172      these "databases" are nothing more than A    172      these "databases" are nothing more than ASCII files:
173                                                   173 
174         datageom/ : tbhcal96.geom, tbhcal96hca    174         datageom/ : tbhcal96.geom, tbhcal96hcal.geom, tbhcal96xtal.geom
175                     store the information abou    175                     store the information about the experimental Hall, 
176                     the HCAL, and the ECAL, re    176                     the HCAL, and the ECAL, respectively.
177                                                   177 
178         dataconf/ : g4testbeamhcal96.conf, tes    178         dataconf/ : g4testbeamhcal96.conf, testbeamhcal96.conf
179                     store the information abou    179                     store the information about which configuration
180                     (HCAL only, or ECAL+HACL)     180                     (HCAL only, or ECAL+HACL) is considered, in the
181                     Simulation and Reconstruct    181                     Simulation and Reconstruction, respectively.
182                                                   182                     
183         dataglobal/ : fmap.tb96, material.cms,    183         dataglobal/ : fmap.tb96, material.cms, rotation.cms
184                     The first one is the magne    184                     The first one is the magnetic field map (how the 
185                     intensity of the magnetic     185                     intensity of the magnetic field, in the direction
186                     orthogonal to the beam dir    186                     orthogonal to the beam direction, varies along
187                     the beam axis). The second    187                     the beam axis). The second one, material.cms, 
188                     keeps the full collection     188                     keeps the full collection of all materials used in 
189                     the CMS detector (not only    189                     the CMS detector (not only in the calorimeters, 
190                     although we are simulating    190                     although we are simulating only them in this example!).
191                     The third one, rotation.cm    191                     The third one, rotation.cms, collects a set of useful
192                     rotation parameters (angle    192                     rotation parameters (angles).  
193                                                   193    
194         datavis/ : tbhcal96.vis, tbhcal96hcal.    194         datavis/ : tbhcal96.vis, tbhcal96hcal.vis, tbhcal96xtal.vis
195              visualization information for, re    195              visualization information for, respectively, the
196                    experimental Hall, HCAL, an    196                    experimental Hall, HCAL, and ECAL.
197                                                   197 
198  --- In order to allow an high degree of flexi    198  --- In order to allow an high degree of flexibility, at the geometry
199      level the user can choose which subsystem    199      level the user can choose which subsystem of the detector setup
200      should be simulated and can activate or d    200      should be simulated and can activate or deactivate the sensitive
201      parts, subsystem by subsystem. This can b    201      parts, subsystem by subsystem. This can be done at run time, 
202      by modifying one of the above database in    202      by modifying one of the above database information, without need 
203      of putting the hands on the code, recompi    203      of putting the hands on the code, recompiling, etc.
204                                                   204 
205  --- There are two "parallel geometry factorie    205  --- There are two "parallel geometry factories": one described by "core" 
206      classes, which are independent from the S    206      classes, which are independent from the Simulation (and therefore
207      can be used, for instance, by the Reconst    207      can be used, for instance, by the Reconstruction); and one which 
208      is specific of the Simulation. In the lat    208      is specific of the Simulation. In the latter case (Geant4 side of
209      the geometry model), all the geometry fac    209      the geometry model), all the geometry factories are derived from the
210      base class CCalG4Albe. Furthermore, using    210      base class CCalG4Albe. Furthermore, using double inheritance, each
211      of them derives also from the counterpart    211      of them derives also from the counterpart in the "core" hierarchy.  
212      The design of the CCalG4Able class helps     212      The design of the CCalG4Able class helps a modular approach and easy
213      interchanging at the level of subdetector    213      interchanging at the level of subdetectors, allowing a straightforward
214      transition from the simulation of the ent    214      transition from the simulation of the entire CMS detector to that of
215      just a part of it, or to a test-beam geom    215      just a part of it, or to a test-beam geometry, as indeed in this example.
216      Of course this modular, flexible, and gen    216      Of course this modular, flexible, and general approach does not come
217      for free: the price to pay here is its co    217      for free: the price to pay here is its complexity, which would be 
218      otherwise unjustified if we limited ourse    218      otherwise unjustified if we limited ourself to the pure simulation
219      of a relatively simple test-beam setup.      219      of a relatively simple test-beam setup.
220                                                   220 
221  --- See "10. Classes Overview" below for a sc    221  --- See "10. Classes Overview" below for a schematic summary of the 
222      various classes involved in the Geometry     222      various classes involved in the Geometry description of this example.
223                                                   223 
224                                                   224 
225 4. Physics processes                              225 4. Physics processes
226 --------------------                              226 --------------------
227                                                   227  
228  The factory physics list is used, therefore t    228  The factory physics list is used, therefore the choice of the physics list
229  is steered by the environmental variable PHYS    229  is steered by the environmental variable PHYSLIST.
230  (Note: if this environmental variable is not     230  (Note: if this environmental variable is not set, the default physics list
231   which is used is FTFP_BERT).                    231   which is used is FTFP_BERT).
232                                                   232  
233                                                   233 
234 5. Particle Generator                             234 5. Particle Generator
235 ---------------------                             235 ---------------------
236                                                   236   
237  The 1996 test-beam has been taken with the fo    237  The 1996 test-beam has been taken with the following particles:
238     --- 225 GeV muons (for calibration)           238     --- 225 GeV muons (for calibration)
239     --- 10 to 300 GeV pions                       239     --- 10 to 300 GeV pions
240     --- 10 to 300 GeV electrons                   240     --- 10 to 300 GeV electrons
241  therefore the standard Geant4 Particle Gun ha    241  therefore the standard Geant4 Particle Gun has been used as primary
242  generator. Notice that, for the sake of keepi    242  generator. Notice that, for the sake of keeping the example not too
243  complicated, the proper simulation of the bea    243  complicated, the proper simulation of the beam profile and 
244  beam contamination have been neglected.          244  beam contamination have been neglected.  
245                                                   245 
246                                                   246 
247 6. Hits                                           247 6. Hits 
248 -------                                           248 -------
249                                                   249  
250  In CMS there are two groups of hits: Tracker-    250  In CMS there are two groups of hits: Tracker-like and Calorimeter-like.
251  Only the latter one appears in this example.     251  Only the latter one appears in this example. 
252  For the same reasons, as seen for the Geometr    252  For the same reasons, as seen for the Geometry, of consistency without 
253  duplication of information and unnecessary co    253  duplication of information and unnecessary coupling between Simulation, 
254  Reconstruction, and Visualization, the simula    254  Reconstruction, and Visualization, the simulation calorimeter hit class,
255  CCalG4Hit, doubly inherits from the common Ge    255  CCalG4Hit, doubly inherits from the common Geant4 abstract class for
256  all hits, G4VHit, and from the "core" (i.e. s    256  all hits, G4VHit, and from the "core" (i.e. simulation independent)
257  CMS calorimeter hit class, CCalHit.              257  CMS calorimeter hit class, CCalHit.
258  A new Hit object is created                      258  A new Hit object is created
259    - for each new particle entering the calori    259    - for each new particle entering the calorimeter;
260    - for each detector unit (i.e cristal or fi    260    - for each detector unit (i.e cristal or fiber or scintillator layer);
261    - for each nanosecond of the shower develop    261    - for each nanosecond of the shower development;
262  The information stored in each CCalHit object    262  The information stored in each CCalHit object is the following:
263    - Entry  : local coordinates of the entranc    263    - Entry  : local coordinates of the entrance point of the particle
264               in the unit where the shower sta    264               in the unit where the shower starts; 
265    - the TrackID  : Identification number of t    265    - the TrackID  : Identification number of the incident particle;
266    - the IncidentEnergy  : kinetic energy of t    266    - the IncidentEnergy  : kinetic energy of that incident particle;    
267    - the UnitID : the identification number of    267    - the UnitID : the identification number of the detector unit
268                   (crystal, or fiber, or scint    268                   (crystal, or fiber, or scintillator layer); 
269    - the TimeSlice : the time interval, in nan    269    - the TimeSlice : the time interval, in nanoseconds, in which the 
270                      hit has been created;        270                      hit has been created;
271    - the EnergyDeposit : the energy deposit in    271    - the EnergyDeposit : the energy deposit in this hit.    
272  Notice that all hit objects created for a giv    272  Notice that all hit objects created for a given shower have the same 
273  values for the first three pieces of informat    273  values for the first three pieces of information.
274                                                   274 
275                                                   275 
276 No Noise and Digitization                         276 No Noise and Digitization 
277 --------------------------                        277 --------------------------
278                                                   278  
279  In order to keep the complexity of this examp    279  In order to keep the complexity of this example to a reasonable 
280  level, both noise and digitization effects ha    280  level, both noise and digitization effects have not been included.
281                                                   281  
282                                                   282 
283 7. User Actions                                   283 7. User Actions
284 ----------------                                  284 ----------------
285                                                   285  
286  In this example. there have been used the fol    286  In this example. there have been used the following User Actions:
287                                                   287 
288  --- G4UserRunAction (the derived, concrete cl    288  --- G4UserRunAction (the derived, concrete class is CCalRunAction):
289      it is used to invoke the Analysis object     289      it is used to invoke the Analysis object at the beginning of
290      the Run, to instantiate it and passing it    290      the Run, to instantiate it and passing it the Run number, and
291      at the end of the Run, to inform it that     291      at the end of the Run, to inform it that the Run is finished
292      and therefore the histograms, ntuples, et    292      and therefore the histograms, ntuples, etc. must be closed.
293                                                   293 
294  --- G4UserEventAction (the derived, concrete     294  --- G4UserEventAction (the derived, concrete class is CCalEndOfEventAction):
295      it is used to examine, at the end of the     295      it is used to examine, at the end of the Event, all collected
296      (calorimeter) hits, extract the various o    296      (calorimeter) hits, extract the various observables which are
297      interesting (to the goal of understanding    297      interesting (to the goal of understanding things like: the effect
298      of magnetic field on scintiallator; choic    298      of magnetic field on scintiallator; choice of the absorber
299      thickness by optimizing resolution versus    299      thickness by optimizing resolution versus containment; impact of
300      the absorber depth in the energy caontain    300      the absorber depth in the energy caontainment; electromagnetic
301      calorimeter contribution in the electron     301      calorimeter contribution in the electron - pion separation; etc.)
302      and finally call the analysis object to s    302      and finally call the analysis object to store such selected
303      information on histograms and/or in the n    303      information on histograms and/or in the ntuple.
304      The name of the class "CCalEndOfEventActi    304      The name of the class "CCalEndOfEventAction" is motivated by the
305      fact that at the beginning of the Event n    305      fact that at the beginning of the Event nothing is done. 
306                                                   306 
307  --- G4UserSteppingAction (the derived, concre    307  --- G4UserSteppingAction (the derived, concrete class is CCalSteppingAction):
308      it is used to extract some "unphysical" i    308      it is used to extract some "unphysical" information (that is not
309      experimentally measurable, although inter    309      experimentally measurable, although interesting for a better 
310      understanding of the shower development),    310      understanding of the shower development), namely the lateral profile 
311      and the deposit as a function of the time    311      and the deposit as a function of the time (see "8.Analysis/Histogramming 
312      for more details"), which is available on    312      for more details"), which is available only from simulation, and then, 
313      at the end of Event, the analysis object     313      at the end of Event, the analysis object is invoked to store such
314      information on histograms.                   314      information on histograms.      
315      Please notice that the stepping action is    315      Please notice that the stepping action is not used to create hits.
316                                                   316 
317  --- G4UserStackingAction (the derived, concre    317  --- G4UserStackingAction (the derived, concrete class is CCalStackingAction):
318      it is used to ensure that the same track     318      it is used to ensure that the same track ID of the particle 
319      originating a shower appears in all hits     319      originating a shower appears in all hits (calorimeter hit objects 
320      of class CCalHit) of the shower, in any c    320      of class CCalHit) of the shower, in any calorimeter part. 
321                                                   321 
322                                                   322 
323 8. Analysis / Histogramming                       323 8. Analysis / Histogramming
324 ----------------------------                      324 ----------------------------
325                                                   325 
326  The analysis part of CompositeCalorimeter is     326  The analysis part of CompositeCalorimeter is kept in class CCalAnalysis,
327  and is based on the g4tool interfaces.           327  and is based on the g4tool interfaces.
328  Both the histograms and the ntuple are saved     328  Both the histograms and the ntuple are saved at the end of the run in the 
329  ROOT file "ccal.root" (default: this can be c    329  ROOT file "ccal.root" (default: this can be changed to XML or to other 
330  formats supported by the g4analysis tools).      330  formats supported by the g4analysis tools). 
331  Please note that in a multiple run session, t    331  Please note that in a multiple run session, the last run always overrides 
332  the output file.                                 332  the output file.
333  What the histograms and the variables of the     333  What the histograms and the variables of the ntuple represent is 
334  explained below:                                 334  explained below:
335                                                   335  
336   Histograms  h100 - h127 : energy deposit (in    336   Histograms  h100 - h127 : energy deposit (in GeV) in the sensitive part
337                           (plastic scintillato    337                           (plastic scintillator layer) of one Hadronic 
338                           calorimeter module (    338                           calorimeter module (there are 28 modules, numbered
339                           from 0 to 27, and th    339                           from 0 to 27, and the corresponding histogram has
340                           ID = 100 + number of    340                           ID = 100 + number of module).
341   Ntuple variables  hcal0 - hcal27 : provide t    341   Ntuple variables  hcal0 - hcal27 : provide the same information.
342                                                   342 
343   Histograms  h200 - h248 : energy deposit (in    343   Histograms  h200 - h248 : energy deposit (in GeV) in one crystal
344                           electromagnetic towe    344                           electromagnetic towers (there are a matrix of
345                           7 x 7 = 49 towers, n    345                           7 x 7 = 49 towers, numbered from 0 to 48, and 
346                           the corresponding hi    346                           the corresponding histogram has 
347                           ID = 200 + number of    347                           ID = 200 + number of tower).
348   Ntuple variables  ecal0 - ecal48 : provide t    348   Ntuple variables  ecal0 - ecal48 : provide the same information.
349                                                   349   
350   Histograms  h300 - h339 : total energy depos    350   Histograms  h300 - h339 : total energy deposit (in GeV) in any 
351                           electromagnetic crys    351                           electromagnetic crystal tower or hadronic module 
352                           (either in a sensiti    352                           (either in a sensitive or insensitive layer)
353                           in one of the 40 nan    353                           in one of the 40 nanosecond time slices: in other
354                           words, histogram  30    354                           words, histogram  300+I , where I = 0 - 39,
355                           contains the total d    355                           contains the total deposit energy between
356                           I and I+1 nanosecond    356                           I and I+1 nanoseconds after the "collision".  
357                           (Notice that the tim    357                           (Notice that the time window considered, 
358                            40 nanoseconds, is     358                            40 nanoseconds, is larger than the LHC 
359                            bunch-crossing of 2    359                            bunch-crossing of 25 nanoseconds.)
360                                                   360   
361   Histograms  h400 - h469 : energy profile (in    361   Histograms  h400 - h469 : energy profile (in GeV), summed over all layers
362                           sensitive (plastic s    362                           sensitive (plastic scintillator) and insensitive
363                           (copper absorber), a    363                           (copper absorber), as a function of the radial
364                           distance (in centime    364                           distance (in centimeter) from the beam axis 
365                           ( ID histo = 400 + r    365                           ( ID histo = 400 + radial distance in cm ).
366                                                   366 
367   Histogram  h4000 : total energy deposit (in     367   Histogram  h4000 : total energy deposit (in GeV) in the sensitive parts
368                     of either the electromagne    368                     of either the electromagnetic or hadronic calorimeters. 
369   Ntuple variable  edep provides the same info    369   Ntuple variable  edep provides the same information.
370                                                   370 
371   Other ntuple variables are the following:       371   Other ntuple variables are the following:  
372        ---  elab : energy (in GeV) of the inci    372        ---  elab : energy (in GeV) of the incident particle.
373        ---  xpos, ypos, zpos : position (in mm    373        ---  xpos, ypos, zpos : position (in mm) from where the projectile
374                                has been shot.     374                                has been shot.
375        ---  edec, edhc : total energy deposit     375        ---  edec, edhc : total energy deposit (in GeV) in the sensitive
376                          parts of, respectivel    376                          parts of, respectively, the electromagnetic 
377                          and hadronic calorime    377                          and hadronic calorimeters. Notice that their
378                          sum  edec+edhc  coinc    378                          sum  edec+edhc  coincides with  edep
379                                                   379 
380   Notice that lateral profile (400-469) and ti    380   Notice that lateral profile (400-469) and time-slice (300-339) 
381   histograms show purely Monte Carlo quantitie    381   histograms show purely Monte Carlo quantities, which cannot be 
382   experimentally measured.                        382   experimentally measured. 
383   Please be careful that the range of the hist    383   Please be careful that the range of the histograms has been chosen
384   in such a way to contain most of the entries    384   in such a way to contain most of the entries, but only few histograms
385   fill a large fraction of that range, whereas    385   fill a large fraction of that range, whereas the remaining majority
386   fill only the first few bins (corresponding     386   fill only the first few bins (corresponding to lower energy), and,
387   therefore, when plotted they look almost emp    387   therefore, when plotted they look almost empty, but they are not,
388   and the results are sensible. We suggest to     388   and the results are sensible. We suggest to plot the ntuple's variables,
389   rather than the histograms, when the same in    389   rather than the histograms, when the same information is available
390   from the ntuple.                                390   from the ntuple.
391                                                   391 
392                                                   392 
393 9. Visualization / GUI                            393 9. Visualization / GUI
394 -----------------------                           394 -----------------------
395                                                   395   
396  If you setup one of the following Geant4 envi    396  If you setup one of the following Geant4 environmental variables:
397     G4VIS_USE_DAWN                                397     G4VIS_USE_DAWN
398     G4VIS_USE_VRML                                398     G4VIS_USE_VRML
399     G4VIS_USE_OPENGLX                             399     G4VIS_USE_OPENGLX
400  which correspond to the use of DAWN, VRML, an    400  which correspond to the use of DAWN, VRML, and OPENGLX, respectively, 
401  as visualization engine of Geant4, and set pr    401  as visualization engine of Geant4, and set properly the corresponding 
402   PATH  as well, it is then possible to visual    402   PATH  as well, it is then possible to visualize the detector and also 
403  some events.                                     403  some events. 
404  To do so, you have to run                        404  To do so, you have to run 
405      >  ./CompositeCalorimeter                    405      >  ./CompositeCalorimeter
406  without input file: you then see the detector    406  without input file: you then see the detector; after that,
407  you can select the particle gun and its energ    407  you can select the particle gun and its energy, in the
408  case you want something different from the th    408  case you want something different from the the default 
409  (which is a 100 GeV pi-), for example:           409  (which is a 100 GeV pi-), for example:
410      Idle> /gun/particle e-                       410      Idle> /gun/particle e-
411      Idle> /gun/energy 200 GeV                    411      Idle> /gun/energy 200 GeV
412  and then run some events, for example:           412  and then run some events, for example:
413      Idle> /run/beamOn 3                          413      Idle> /run/beamOn 3
414                                                   414 
415  The tracks that are shown include both charge    415  The tracks that are shown include both charged and neutral particles 
416  of any momentum: if you want instead only cha    416  of any momentum: if you want instead only charged, or only neutral, 
417  then you have simply to edit  src/CCalEndOfEv    417  then you have simply to edit  src/CCalEndOfEventAction.cc 
418  at the end of the method  EndOfEventAction  a    418  at the end of the method  EndOfEventAction  and uncomment the line 
419  where the condition on the charge is made (it    419  where the condition on the charge is made (it should then be 
420  straighforward to eventual add some other con    420  straighforward to eventual add some other conditions, for example 
421  if you want to see only those particles that     421  if you want to see only those particles that satisfy certain 
422  kinematic conditions).                           422  kinematic conditions). 
423                                                   423  
424  Rather than to specify "by hand" the type of     424  Rather than to specify "by hand" the type of particle gun,
425  its energy, and the number of events, it is p    425  its energy, and the number of events, it is possible to have
426  a very simple GUI (graphical user interface)     426  a very simple GUI (graphical user interface) from which to make 
427  such choices, between a limited set of possib    427  such choices, between a limited set of possibilities, via menus.
428  Such GUI is based on Motif XmCommand widget,     428  Such GUI is based on Motif XmCommand widget, but it would be 
429  straightforward, eventually, to make the nece    429  straightforward, eventually, to make the necessary changes 
430  in order to use a different one.                 430  in order to use a different one.
431  The only thing you need to do to get the GUI     431  The only thing you need to do to get the GUI is to setup 
432  the following Geant4 environmental variables:    432  the following Geant4 environmental variables:  
433    G4UI_BUILD_XM_SESSION=1                        433    G4UI_BUILD_XM_SESSION=1
434    G4UI_USE_XM=1                                  434    G4UI_USE_XM=1
435  Then, if you run the executable without speci    435  Then, if you run the executable without specifying a macro file
436  (like test.g4mac):                               436  (like test.g4mac):
437      >  $G4WORKDIR/bin/$G4SYSTEM/CompositeCalo    437      >  $G4WORKDIR/bin/$G4SYSTEM/CompositeCalorimeter
438  a window automatically pops out, with the men    438  a window automatically pops out, with the menus where you
439  can make your selection of particle type, ene    439  can make your selection of particle type, energy, and number 
440  of events to be run.                             440  of events to be run. 
441                                                   441 
442                                                   442 
443 10. Classes Overview                              443 10. Classes Overview
444 ---------------------                             444 ---------------------
445                                                   445 
446  This is a schematic overview of the classes d    446  This is a schematic overview of the classes defined in this example:
447                                                   447 
448   CCalPrimaryGeneratorAction                      448   CCalPrimaryGeneratorAction
449   CCalPrimaryGeneratorMessenger                   449   CCalPrimaryGeneratorMessenger
450   User action for primaries generator.            450   User action for primaries generator.   
451                                                   451 
452   CCalDetectorConstruction                        452   CCalDetectorConstruction
453   CCalAMaterial                                   453   CCalAMaterial
454   CCalDataSet                                     454   CCalDataSet
455   CCalDetector                                    455   CCalDetector
456   CCalEcal                                        456   CCalEcal
457   CCalEcalOrganization                            457   CCalEcalOrganization
458   CCalG4Able                                      458   CCalG4Able
459   CCalG4Ecal                                      459   CCalG4Ecal
460   CCalG4Hall                                      460   CCalG4Hall
461   CCalG4Hcal                                      461   CCalG4Hcal
462   CCalGeometryConfiguration                       462   CCalGeometryConfiguration
463   CCalHall                                        463   CCalHall
464   CCalHcal                                        464   CCalHcal
465   CCalHcalOrganization                            465   CCalHcalOrganization
466   CCalMagneticField                               466   CCalMagneticField
467   CCalMaterial                                    467   CCalMaterial
468   CCalMaterialFactory                             468   CCalMaterialFactory
469   CCalRotationMatrixFactory                       469   CCalRotationMatrixFactory
470   CCalVOrganization                               470   CCalVOrganization
471   CCalVisManager                                  471   CCalVisManager
472   CCalVisualisable                                472   CCalVisualisable
473   CCaloOrganization                               473   CCaloOrganization
474   CCalutils                                       474   CCalutils
475   Geometry and material definitions for the de    475   Geometry and material definitions for the detector.
476         Notice in particular that:                476         Notice in particular that:
477           CCalHall, CCalEcal, CCalHcal derive     477           CCalHall, CCalEcal, CCalHcal derive from CCalDetector;
478           CCalG4Hall, CCalG4Ecal, CCalG4Hcal d    478           CCalG4Hall, CCalG4Ecal, CCalG4Hcal derive from the above 
479              corresponding classes and from CC    479              corresponding classes and from CCalG4Able;
480           CCalEcalOrganization, CCalHcalOrgani    480           CCalEcalOrganization, CCalHcalOrganization derive from
481              CCalVOrganization : each sensitiv    481              CCalVOrganization : each sensitive cell has an unique
482              number for detector organization     482              number for detector organization (this is a software
483              ID not an hardware/electronic one    483              ID not an hardware/electronic one).
484                                                   484   
485   CCalHit                                         485   CCalHit
486   CCalG4Hit                                       486   CCalG4Hit
487   CCalG4HitCollection                             487   CCalG4HitCollection
488   CCalSDList                                      488   CCalSDList
489   CCalSensAssign                                  489   CCalSensAssign
490   CCalSensitiveConfiguration                      490   CCalSensitiveConfiguration
491   CCalSensitiveDetectors                          491   CCalSensitiveDetectors
492   CCaloSD                                         492   CCaloSD
493         Hit and Sensitive Detectors.              493         Hit and Sensitive Detectors. 
494         Notice in particular that:                494         Notice in particular that:
495           CCalG4Hit derives from G4VHit and CC    495           CCalG4Hit derives from G4VHit and CCalHit;
496           CCaloSD derives from G4VSensitiveDet    496           CCaloSD derives from G4VSensitiveDetector.          
497                                                   497 
498   CCalActionInitializer                           498   CCalActionInitializer
499         User-action initialization.               499         User-action initialization.
500                                                   500   
501   CCalAnalysis                                    501   CCalAnalysis
502   Analysis manager class.                         502   Analysis manager class.
503                                                   503 
504   CCalRunAction                                   504   CCalRunAction
505   User run action class.                          505   User run action class.
506                                                   506 
507   CCalEndOfEventAction                            507   CCalEndOfEventAction
508   User event action class.                        508   User event action class.
509                                                   509 
510   CCalStackingAction                              510   CCalStackingAction
511         User Stacking action class.               511         User Stacking action class.
512                                                   512 
513   CCalSteppingAction                              513   CCalSteppingAction
514         User Stepping action class.               514         User Stepping action class.